204 Parameters
06.02
STATUS WORD 2
Drive status word 2.
0x0000...0xFFFF Status word 2
1 = 1
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Bit
Name
Value Information
0
START ACT
1
Drive start command is active.
0
Drive start command is inactive.
1
STOP ACT
1
Drive stop command is active.
0
Drive stop command is inactive.
2
READY RELAY
1
Ready to function: run enable signal on, no fault,
emergency stop signal off, no ID run inhibition.
0
Not ready to function.
3
MODULATING
1
Modulating: IGBTs are controlled, ie, the drive is
RUNNING.
0
No modulation: IGBTs are not controlled.
4
REF RUNNING 1
Normal operation is enabled. Running. Drive follows the
given reference.
0
Normal operation is disabled, Drive is not following the
given reference (eg, in magnetisation phase drive is
modulating).
5
JOGGING*
1
Jogging function 1 or 2 is active.
0
Jogging function is inactive.
6
OFF1
1
Emergency stop OFF1 is active.
0
Emergency stop OFF1 is inactive.
7
RESERVED
8
START INH
NOMASK
1
Non-maskable start inhibit is active.
0
No start inhibit (non-maskable)
9
CHRG REL
CLOSED
1
Charging relay is closed.
0
Charging relay is open.
10
STO ACT
1
Safe torque off function is active. See parameter
STO DIAGNOSTIC.
0
Safe torque off function is inactive.
11
RESERVED
12
RAMP IN 0
1
Ramp Function Generator input is forced to zero.
0
Normal operation.
13
RAMP HOLD
1
Ramp Function Generator output is held.
0
Normal operation.
14
RAMP OUT 0
1
Ramp Function Generator output is forced to zero.
0
Normal operation.
15
DATA LOGGER
ON
1
The drive data logger is on and has not been triggered.
0
The drive data logger is off, or its post-trigger time has
not yet elapsed. See the
DriveStudio user’s manual
.
* Internally used for evacuation and inspection mode operation.
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...