246 Parameters
Alarm
Drive running:
The drive trips on SAFE TORQUE OFF when one or
both of the STO signals is lost.
Drive stopped:
The drive generates a SAFE TORQUE OFF alarm if
both STO signals are absent. If only one of the
signals is lost, the drive trips on STO1 LOST or
STO2 LOST.
2
No
Drive running:
The drive trips on SAFE TORQUE OFF when one or
both of the STO signals is lost.
Drive stopped:
No action if both STO signals are absent. If only one
of the signals is lost, the drive trips on STO1 LOST or
STO2 LOST.
3
Only Alarm
The drive generates a SAFE TORQUE OFF alarm if
both STO signals are absent. If only one of the
signals is lost, the drive trips on STO1 LOST or
STO2 LOST.
4
46.06
CROSS
CONNECTION
Selects how the drive reacts to an incorrect input
power and motor cable connection (ie, an input
power cable is connected to a drive motor
connection).
Fault /
No
No reaction.
0
Fault
Drive trips on CABLE CROSS CON fault.
1
46.07
MOT TEMP PROT
Selects how the drive reacts when motor
overtemperature is detected.
Fault /
No
Inactive.
0
Alarm
The drive generates alarm MOTOR TEMPERATURE
when the temperature exceeds the alarm level
defined by parameter
MOT TEMP ALM LIM.
1
Fault
The drive generates alarm MOTOR TEMPERATURE
or trips on fault MOTOR OVERTEMP when the
temperature exceeds the alarm/fault level defined by
parameter
MOT TEMP ALM LIM /
MOT
TEMP FLT LIM.
2
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...