268 Parameters
81.09
LVL MAX TIME
Defines the maximum time the drive can run at the
leveling speed. If the stop command has not been
received before this time period elapses, the
Leveling overtime stop function activates an
emergency stop command (OFF3). The function is
enabled when the value of this parameter is > 0.
0.0 s /
0.0…25.0 s
Maximum leveling time for the Leveling overtime stop
function.
10 = 1 s
83
82 SMART
SLOWDOWN
Parameters related to the Smart slowdown function.
See also section
.
82.01
SMART SLOWDN
SEL
Enables/disables the Smart slowdown function.
NOT SEL /
NOT SEL
Smart slowdown function is not enabled.
0
ESTIMATED
Smart slowdown function is enabled with the
estimated speed. The distance traveled is calculated
by integrating the actual speed.
1
ENCODER
Smart slowdown function is enabled with an encoder.
The distance traveled is based on the actual position
of the encoder (
POS ACT).
2
82.02
LV STOP SWC
DIST
Defines the distance between leveling and stopping
switches.
0.00 m /
0.00…100.00 m
Distance between leveling and stopping switches.
100 = 1 m
82.03
SAFETY MARGIN
Defines what percentage of parameter
is used
as the safety distance when the Smart slowdown
function is enabled. Safety distance is the distance
which must be run with the steady state leveling
speed.
0.00 % /
0.00…100.00%
Safety margin in percentages.
100 = 1%
90
90 ENC MODULE
SEL
Settings for encoder activation, emulation, TTL echo,
and communication fault detection.
90.01
ENCODER SEL
Activates the communication to optional
encoder/resolver interface.
None /
None
Inactive.
0
FEN-01 TTL+
Communication active. Module type: FEN-01 TTL
Encoder interface Module. Input: TTL encoder input
with commutation support (X32). See parameter
group
1
FEN-01 TTL
Communication active. Module type: FEN-01 TTL
Encoder interface Module. Input: TTL encoder input
(X31). See parameter group
.
2
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Содержание ACL30
Страница 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Страница 4: ......
Страница 20: ...20 Safety instructions ...
Страница 34: ...34 Operation principle and hardware description ...
Страница 42: ...42 Planning the cabinet installation ...
Страница 60: ...60 Planning the electrical installation ...
Страница 126: ...126 Using the control panel ...
Страница 318: ...318 Maintenance ...
Страница 334: ...334 The Safe torque off function ...
Страница 338: ...338 Mains chokes ...
Страница 342: ...342 EMC filters ...
Страница 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Страница 349: ...Dimension drawings 349 ...
Страница 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Страница 351: ...Dimension drawings 351 ...
Страница 352: ...Dimension drawings 352 Frame size D ...
Страница 354: ...354 Dimension drawings EMC filters JFI 0x ...
Страница 356: ...356 Dimension drawings Brake resistors JBR xx ...
Страница 358: ...358 Dimension drawings ...
Страница 360: ...Contact us www abb com drives www abb com drivespartners 3AXD50000036355 Rev B EN EFFECTIVE 2016 11 21 ...