ACH580 E-Clipse bypass and packaged drive user manual
131
Embedded fieldbus
AV31
SPD OUT PCT
This object indicates the drive’s output
speed, as a percentage of rated.
Percent
R
AV32
CUR OUT PCT
This object indicates the drive’s output
current, as a percentage of rated.
Percent
R
AV33
MAX
CURRENT
This object indicates the drive’s
maximum output current.
Percent
R
AV40
PRC PID FBK
RD
This object indicates the drive’s process
PID feedback.
Percent
R
AV41
PRC PID STPT
RD
This object indicates the drive’s process
PID setpoint.
Percent
R
AV42
PRC PID STPT
WR
This object sets the drive’s process PID
setpoint.
Percent
C
AV43
PRC PID FBK
WR
This object sets the drive’s process PID
feedback.
Percent
C
AV44
PRC PID OUT
This object indicates the drive’s process
PID output.
Percent
R
AV45
PID SET1 GAIN This object sets the drive’s process PID
set1 proportional gain.
None
W
AV46
PID SET1
ITIME
This object sets the drive’s process PID
set1 integration time.
Seconds
W
AV49
PRC PID DEV
MON
This object indicates the drive’s process
PID deviation.
Percent
R
AV53
PID SET2 GAIN This object sets the drive’s process PID
set2 proportional gain.
None
W
AV54
PID SET2
ITIME
This object sets the drive’s process PID
set2 integration time.
Seconds
W
AV55
EXT PID FBK
RD
This object indicates the drive’s external
PID feedback.
Percent
R
AV56
EXT PID STPT
RD
This object indicates the drive’s external
PID setpoint.
Percent
R
AV59
EXT PID OUT
This object indicates the drive’s external
PID output.
Percent
R
AV60
EXT PID
PGAIN
This object sets the drive’s external PID
proportional gain.
None
W
AV61
EXT PID ITIME
This object sets the drive’s external PID
integration time.
Seconds
W
AV64
EXT PID DEV
MON
This object indicates the drive’s external
PID deviation.
Percent
R
AV130
KWH CUR HR
This object indicates the drive’s energy
usage for the current hour.
kWh
R
AV131
KWH PRV HR
This object indicates the drive’s energy
usage for the previous hour.
kWh
R
AV132
KWH CUR DAY This object indicates the drive’s energy
usage for the current day.
kWh
R
AV133
KWH PRV DAY
This object indicates the drive’s energy
usage for the previous day.
kWh
R
Instance
ID
Object Name
Description
Units
Present Value
Access Type
Содержание ACH580 Series
Страница 2: ......
Страница 11: ...ACH580 BCR BDR VCR VDR E Clipse Bypass Drives 1 200 HP ...
Страница 35: ...26 ACH580 E Clipse bypass and packaged drive user manual Installation ...
Страница 43: ...34 ACH580 E Clipse bypass and packaged drive user manual Start up ...
Страница 67: ...58 ACH580 E Clipse bypass and packaged drive user manual Application macros ...
Страница 193: ...184 ACH580 E Clipse bypass and packaged drive user manual Fieldbus adapter ...
Страница 207: ...198 ACH580 E Clipse bypass and packaged drive user manual Diagnostics ...
Страница 229: ...220 ACH580 E Clipse bypass and packaged drive user manual Technical data ...
Страница 231: ...ACH580 PCR PDR Packaged Drives with Disconnect 1 200 HP ...
Страница 243: ...234 ACH580 E Clipse bypass and packaged drive user manual Installation ...
Страница 256: ......