Case studies
System Manual
│152
7.3.5
Connection of router / WLAN-WLAN
DHCP
LAN 1
WLAN
Master
24 V DC
02
03
04
05
06
07
08
Fig. 136: Adding a unit network router / WLAN-WLAN
This version allows up to 7 additional indoor stations (02 - 08) to be added in a unit as extension
unit.
No power supply can be set up for a WLAN connection. That is why a 24 V power supply is
required for the additional indoor station.
The IP addresses and the sub-net masks of the unit network are assigned automatically by the
DHCP function of the router.
Use the following steps to add additional indoor stations:
1. Search for devices in the "Smart Access Point".
– Connect a PC with the "Smart Access Point".
– In the main menu of the "Smart Access Point", change to the "Door communication"
function.
– Search for all devices in the building network including the master indoor station.
Change to further indoor stations
2. Configure the additional indoor station (extension unit) for operation.
– Change to the "Settings" / "Local settings" function in the additional indoor station.
– Set the following points in the "Local settings" function:
■
Physical address (physical address, see chapter 6.4.3 “Reconnect the "Smart
Access Point"“ on page 105).
Apart from the device number the physical address of the extension unit is identical
with the master address.
■
Mode: Extension unit
■
Device number: For the first additional indoor station the device number is set
automatically on 02. Each additional indoor station must be correspondingly counted
upwards.
Содержание 2TMA130050B0055
Страница 1: ...System Manual 23 02 2021 ABB Welcome IP Branding Release 2018 01 01 ...
Страница 182: ...Case studies System Manual 182 P E o P Up Link P E o Fig 172 Overview Perimeters ...
Страница 188: ...Notes System Manual 188 9 Notes ...
Страница 190: ...Index System Manual 190 T Table installation 51 54 W Wall mounting 52 Wiring of a ABB Welcome IP system 11 ...