Case studies
System Manual
│161
POE
1
2
4
3
5
6
7
8
9
10
15
14
13
12
11
Fig. 146: Physical addressing: Multifamily house with 10 parties
The counting sequence of the physical addresses can be freely selected. However, it should be
noted that no physical address can be assigned twice to a device type. This would cause
conflict.
Physical Address
Settings
Building No.
Floor No.
Units No.
Device ID
Mode /
Device type
1
001
―
―
01
Outdoor station /
―
2
001
―
―
01
― / Building IP
actuator
3
―
―
―
―
Multi-unit house /
commercial / ―
4
001
―
―
02
― / Building IP
actuator