Commissioning
System Manual
│118
6.7.2
Outdoor station with buttons / display
Resetting becomes necessary, for example, when they have already been integrated in a
system or are to be integrated in a new system.
Carry out the following steps to reset devices:
1. Briefly interrupt the power supply at the rear of the device.
– The device reboots.
– The LEDs in the camera field on the front light up permanently during the boot up.
– The LEDs go out when the device has booted.
2. Press the "Reset" button on the rear of the device directly after the LEDs have gone out and
keep it pressed.
– The LEDs in the camera field on the front flash.
– Keep the "Reset" button pressed until two beeps have sounded.
– Approximately 15 seconds pass until the first beep. Approximately another 8
seconds pass until the second beep.
– The existing data are reset.
– The device reboots.