Case studies
System Manual
│147
4. Prepare the home network.
■
For this, set up the LAN connections of the additional indoor stations (extension units) in
the "Local settings" / "Home network port".
– LAN/WLAN version: Set it on "LAN".
– LAN/LAN version: Set it on the 1st LAN connection "LAN1".
5. Switch the extension unit over to the static IP address and adjust the IP address.
– In the additional indoor station change to the "System settings" / "Network settings"
function.
– Set a fixed IP address and the sub-net mask in the "Network settings" function.
– Disable the "Obtain IP address automatically" function.
– IP address: 192.168.1.201
– Sub-net mask: 255.255.255.0
Change to the "Smart Access Point".
6. Add the extension unit manually to the project in the "Smart Access Point".
– By saving in step two of adding, the extension unit receives a certificate from the "Smart
Access Point".
Fig. 131: Indoor station: Certificate
– Check on the additional indoor station (extension unit) whether it has received the
certificate.