20
This water heater is provided with a properly rated/sized and
F
erti
¿
ed
F
ombination temperature - pressure (T&P) relief valve
by the manufa
F
turer
See Temperature-Pressure Relief Valve
on pages 14-15 for information on repla
F
ement and other
requirements
Water Damage Hazard
Temperature-Pressure Relief Valve discharge
pipe must terminate at adequate drain.
CAUTION
Install a dis
F
harge pipe between the T&P valve dis
F
harge
opening and a suitable
À
oor drain
Do not
F
onne
F
t dis
F
harge
piping dire
F
tly to the drain unless a 6
´
(15
2
F
m) air gap is
provided
To prevent bodily injury, hazard to life, or property
damage, the relief valve must be allowed to dis
F
harge water
in adequate quantities should
F
ir
F
umstan
F
es demand
If the
dis
F
harge pipe is not
F
onne
F
ted to a drain or other suitable
means, the water
À
ow may
F
ause property damage
T&P VALVE DISCHARGE PIPE REQUIREMENTS:
Shall not be smaller in size than the outlet pipe size of the
valve, or have any redu
F
ing
F
ouplings or other restri
F
tions
Shall not be plugged or blo
F
ked
Shall not be exposed to freezing temperatures
Shall be of material listed for hot water distribution
Shall be installed so as to allow
F
omplete drainage of both
Temperature-Pressure Relief Valve and the dis
F
harge pipe
Must terminate a maximum of six in
F
hes above a
À
oor
drain or external to the building
In
F
old
F
limates, it is
re
F
ommended that the dis
F
harge pipe be terminated at an
adequate drain inside the building
Shall not have any valve or other obstru
F
tion between the
relief valve and the drain
INSTALLATION DIAGRAMS - TOP INLET/OUTLET USAGE
Use of the top inlet water
F
onne
F
tion requires an inlet dip tube
(refer to Figure 17)
The tube is supplied in the heater
Follow
F
aution labels if applying heat to this
¿
tting
Do not allow pipe
dope to
F
onta
F
t the plasti
F
tube during installation
TUBE INLET INSTALLATION
FIGURE 17.
BURNER INSTALLATION
Remove the fa
F
tory-installed insulation
F
overing the
F
ombustion
F
hamber opening
(A utility knife is useful for
F
utting out the
insulation)
Cut the insulation ba
F
k even with the ja
F
ket opening
Install the
À
ange gasket (whi
F
h is usually taped to the heater ja
F
ket)
over the three bolts protruding from the tank at the
F
ombustion
F
hamber opening
Remove hardware (3 hex nuts, 3
À
at washers, and 3 lo
F
k washers)
from the shipping bag atta
F
hed to the heater
¶
s ele
F
tri
F
al
F
onduit
Begin assembling the power burner to the tank by pla
F
ing the power
burner nozzle in the
F
ombustion
F
hamber opening
Slide the nozzle
into the tank and rotate the mounting
À
ange to engage the mounting
bolts, refer to Figure 18
Then, pla
F
e the
À
at washers followed by
the lo
F
k washers, and
¿
nally the hex nuts on the mounting bolts
Hand tighten the nuts
Then gradually tighten ea
F
h nut alternating
between the 3 mounting bolts
Do not over tighten as damage to
the
À
ange gasket or to the tank may result
Refer to Figure 18
POWER BURNER INSTALLATION
FIGURE 18.