Chapter 6 Tutorials
MES3500 Series User’s Guide
61
3
Click
Advanced Application > Errdisable > Errdisable Detect
, select
Active
for cause
ARP
and
inactive-port
as the mode. Then click
Apply
.
4
Click
Advanced Application > Errdisable > Errdisable Recovery
, select
Active
and
Timer
Status
for
loopguard
and
ARP
entries. Also enter 180 (180 seconds = 3 minutes) in the
Interval
field for both entries. Then click
Apply
.