Chapter 40 Access Control
MES3500 Series User’s Guide
314
Security Level
Select whether you want to implement authentication and/or encryption for SNMP
communication from this user. Choose:
•
noauth
-to use the username as the password string to send to the SNMP manager.
This is equivalent to the Get, Set and Trap Community in SNMP v2c. This is the lowest
security level.
•
auth
- to implement an authentication algorithm for SNMP messages sent by this user.
•
priv
- to implement authentication and encryption for SNMP messages sent by this
user. This is the highest security level.
Note: The settings on the SNMP manager must be set at the same security level or higher
than the security level settings on the Switch.
Authentication
Select an authentication algorithm.
MD5
(Message Digest 5) and
SHA
(Secure Hash
Algorithm) are hash algorithms used to authenticate SNMP data. SHA authentication is
generally considered stronger than MD5, but is slower.
Password
Enter the password of up to 32 ASCII characters for SNMP user authentication.
Note that as you type a password, the screen displays an asterisk (*) for each character
you type.
Privacy
Specify the encryption method for SNMP communication from this user. You can choose one
of the following:
•
DES
- Data Encryption Standard is a widely used (but breakable) method of data
encryption. It applies a 56-bit key to each 64-bit block of data.
•
AES
- Advanced Encryption Standard is another method for data encryption that also
uses a secret key. AES applies a 128-bit key to 128-bit blocks of data.
Password
Enter the password of up to 32 ASCII characters for encrypting SNMP packets.
Note that as you type a password, the screen displays an asterisk (*) for each character
you type.
Group
SNMP v3 adopts the concept of View-based Access Control Model (VACM) group. SNMP
managers in one group are assigned common access rights to MIBs. Specify in which SNMP
group this user is.
admin
- Members of this group can perform all types of system configuration, including the
management of administrator accounts.
readwrite
- Members of this group have read and write rights, meaning that the user can
create and edit the MIBs on the Switch, except the user account and AAA configuration.
readonly
- Members of this group have read rights only, meaning the user can collect
information from the Switch.
Add
Click
Add
to insert the entry in the summary table below and save your changes to the
Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power,
so use the
Save
link on the top navigation panel to save your changes to the non-volatile
memory when you are done configuring.
Cancel
Click
Cancel
to reset the fields to your previous configuration.
Clear
Click
Clear
to reset the fields to the factory defaults.
Index
This is a read-only number identifying a login account on the Switch. Click on an index
number to view more details and edit an existing account.
Username
This field displays the username of a login account on the Switch.
Security
Level
This field displays whether you want to implement authentication and/or encryption for
SNMP communication with this user.
Authenticati
on
This field displays the authentication algorithm used for SNMP communication with this
user.
Privacy
This field displays the encryption method used for SNMP communication with this user.
Group
This field displays the SNMP group to which this user belongs.
Table 151
Management > Access Control > SNMP > User (continued)
LABEL
DESCRIPTION
Summary of Contents for MES3500 Series
Page 16: ...Table of Contents MES3500 Series User s Guide 16 Appendix C Legal Information 357 Index 362...
Page 17: ...17 PART I User s Guide...
Page 72: ...72 PART II Technical Reference...
Page 178: ...Chapter 22 Policy Rule MES3500 Series User s Guide 178 Figure 98 Policy Example EXAMPLE...
Page 360: ...Appendix C Legal Information MES3500 Series User s Guide 360 Environmental Product Declaration...