Chapter 7 Cables
IES4005M User’s Guide
56
7.7.4 Specifications
The following table lists the specifications of the Telco 64 subscriber cables.
7.8 Fiber Cable
Fiber optic cable connects the management card to the upstream device.
7.8.1 Application
The fiber optic cable carries optical signals. The connections are as follows:
• One end of the fiber optic cable connects to the transceiver in the management card’s SFP slot.
• The other end of the fiber optic cable connects to a peer Gigabit Ethernet device.
7.8.1.1 Connection to the Gigabit Ethernet Backbone Network
The IES with MSC1002G delivers services originating from an active Gigabit Ethernet network.
Duplex optical fiber cable with LC (Lucent Connector) connectors or copper Ethernet cable carries
upstream and downstream traffic between the MSC1002G card and the active Gigabit Ethernet
network. MSC1002G converts the downstream traffic from the signal sent by the peer Gigabit
Ethernet device to the required service format for delivery to the subscriber. MSC1002G also
converts the upstream traffic back to an optical or electronic signal for transport over the Gigabit
Ethernet network.
The SFP slots have priority over the Gigabit ports. This means that if a SFP transceiver and the
corresponding Gigabit port are connected at the same time, the Gigabit port will be disabled.
7.8.1.1.1 Appearance
The following figure shows a duplex fiber optic cable with LC connectors.
Table 43
Telco 64 Subscriber Cable Specifications
ITEM
DESCRIPTION
Connectors (X1/X2)
Telco 64 connector, bare or RJ-11
Type
Symmetrical twisted pair
Wire diameter of the inner conductor
0.400 mm
Wire gauge of the inner conductor
26 AWG
Number of wires
64
Summary of Contents for IES4005M
Page 4: ...Contents Overview IES4005M User s Guide 4...
Page 13: ...13 PART I Introduction and Hardware Installation...
Page 14: ...14...
Page 20: ...Chapter 2 IES Chassis IES4005M User s Guide 20...
Page 38: ...Chapter 4 Line Cards IES4005M User s Guide 38...
Page 42: ...Chapter 5 Power Supply Unit IES4005M User s Guide 42...
Page 46: ...Chapter 6 Fan Module IES4005M User s Guide 46...
Page 58: ...Chapter 7 Cables IES4005M User s Guide 58...
Page 64: ...Chapter 8 Hardware Installation IES4005M User s Guide 64 Figure 36 Removing a Line Card 1 2 3...
Page 65: ...65 PART II Commands...
Page 66: ...66...
Page 78: ...Chapter 9 The CLI IES4005M User s Guide 78...
Page 124: ...Chapter 13 Switch Features IES4005M User s Guide 124...
Page 150: ...Chapter 20 MTU IES4005M User s Guide 150...
Page 164: ...Chapter 23 Static Route IES4005M User s Guide 164...
Page 192: ...Chapter 25 VLAN IES4005M User s Guide 192...
Page 204: ...Chapter 26 VoIP IES4005M User s Guide 204...
Page 210: ...Chapter 27 IEEE 802 1x Authentication IES4005M User s Guide 210...
Page 211: ...211 PART III Troubleshooting Specifications Appendices and Index...
Page 212: ...212...
Page 220: ...Chapter 28 Hardware Troubleshooting IES4005M User s Guide 220...