An example is shown below. Line 1 and Line 2 are in the same cable binder. Crosstalk occurs when
the signal flows and is near to CPE (A)’s location. Besides, higher Line 1 PSD causes higher
interference to the Line 2. CO receives signal with higher attenuation. With UPBO enabled on the
CPE (A), it decreases the PSD level and reduces the crosstalk impact on long loops.
Figure 42
UPBO Resolves Upstream Far-End Crosstalk
DPBO
VDSL signals may interfere with other services (such as ISDN, ADSL or ADSL2 provided by other
devices) on the same bundle of lines due to downstream far-end crosstalk. DPBO (Downstream
Power Back Off) can reduce performance degradation by changing the PSD level on the VDSL
switch(es) at street cabinet level.
ISDN in Europe uses a frequency range of up to 80 kHz, while ISDN in Japan uses a frequency
range of up to 640 kHz. ADSL utilizes the 1.1 MHz band. Both ADSL2 and ADSL 2+ utilize the 2.2
MHz band.
An example is shown next. VDSL Line 1 and ADSL Line 2 are in the same binder. Crosstalk occurs
when the ADSL signal flows from CO (B) and is near to CO (A)’s ONU (Optical Network Unit)
location. Besides, higher Line 1 PSD causes higher interference to the Line 2. CPE (B) receives
signal with higher attenuation. With DPBO enabled on the CO (A), it decreases the PSD level and
reduces the crosstalk impact on other service lines.
Central
CPE (A)
CPE (B)
Site (CO)
Line 1 (150 m)
Line 2 (600 m)
No-UPBO
UPBO
Summary of Contents for IES4005M
Page 4: ...Contents Overview IES4005M User s Guide 4...
Page 13: ...13 PART I Introduction and Hardware Installation...
Page 14: ...14...
Page 20: ...Chapter 2 IES Chassis IES4005M User s Guide 20...
Page 38: ...Chapter 4 Line Cards IES4005M User s Guide 38...
Page 42: ...Chapter 5 Power Supply Unit IES4005M User s Guide 42...
Page 46: ...Chapter 6 Fan Module IES4005M User s Guide 46...
Page 58: ...Chapter 7 Cables IES4005M User s Guide 58...
Page 64: ...Chapter 8 Hardware Installation IES4005M User s Guide 64 Figure 36 Removing a Line Card 1 2 3...
Page 65: ...65 PART II Commands...
Page 66: ...66...
Page 78: ...Chapter 9 The CLI IES4005M User s Guide 78...
Page 124: ...Chapter 13 Switch Features IES4005M User s Guide 124...
Page 150: ...Chapter 20 MTU IES4005M User s Guide 150...
Page 164: ...Chapter 23 Static Route IES4005M User s Guide 164...
Page 192: ...Chapter 25 VLAN IES4005M User s Guide 192...
Page 204: ...Chapter 26 VoIP IES4005M User s Guide 204...
Page 210: ...Chapter 27 IEEE 802 1x Authentication IES4005M User s Guide 210...
Page 211: ...211 PART III Troubleshooting Specifications Appendices and Index...
Page 212: ...212...
Page 220: ...Chapter 28 Hardware Troubleshooting IES4005M User s Guide 220...