Chapter 24 VDSL
IES4005M User’s Guide
175
xtuc-15min-fecs-threshold
<
threshold
>
Configures the number of Forward Error Correction Seconds
(FECS) allowed on the system within 15 minutes. 0-900, default:
0.
C
13
xtuc-15min-es-threshold
<
threshold
>
Configures the number of Errored Seconds (ES) allowed on the
system within 15 minutes. 0-900, default: 0.
C
13
xtuc-15min-lofs-threshold
<
threshold
>
Configures the number of Loss of Frame Seconds (LOFS) allowed
on the system within 15 minutes. 0-900, default: 0.
C
13
xtuc-15min-lprs-threshold
<
threshold
>
Configures the number of Loss of Power Seconds (LPRS) allowed
on the system within 15 minutes. 0-900, default: 0.
C
13
xtuc-15min-ses-threshold
<
threshold
>
Configures the number of Severely Errored Seconds (SES) allowed
on the system within 15 minutes. 0-900, default: 0.
C
13
xtuc-15min-loss-threshold
<
threshold
>
Configures the number of Loss of Signal Seconds (LoSS) allowed
on the system within 15 minutes. 0-900, default: 0.
C
13
xtuc-15min-uas-threshold
<
threshold
>
Configures the number of UnAvailable Seconds (UAS) errors
allowed on the system within 15 minutes. 0-900, default: 0.
C
13
xtur-15min-fecs-threshold
<
threshold
>
Configures the number of Forward Error Correction Seconds
(FECS) allowed on subscriber devices within 15 minutes. 0-900,
default: 0.
C
13
xtur-15min-es-threshold
<
threshold
>
Configures the number of Errored Seconds (ES) allowed on
subscriber devices within 15 minutes. 0-900, default: 0.
C
13
xtur-15min-lofs-threshold
<
threshold
>
Configures the number of Loss of Frame Seconds (LOFS) allowed
on subscriber devices within 15 minutes. 0-900, default: 0.
C
13
xtur-15min-lprs-threshold
<
threshold
>
Configures the number of Loss of Power Seconds (LPRS) allowed
on subscriber devices within 15 minutes. 0-900, default: 0.
C
13
xtur-15min-ses-threshold
<
threshold
>
Configures the number of Severely Errored Seconds (SES) allowed
on subscriber devices within 15 minutes. 0-900, default: 0.
C
13
xtur-15min-loss-threshold
<
threshold
>
Configures the number of Loss of Signal Seconds (LoSS) allowed
on subscriber devices within 15 minutes. 0-900, default: 0.
C
13
xtur-15min-uas-threshold
<
threshold
>
Configures the number of UnAvailable Seconds (UAS) errors
allowed on subscriber devices within 15 minutes. 0-900, default:
0.
C
13
15min-failed-full-init-
threshold <
threshold
>
Configures the number of times a full initialization is allowed to fail
on subscriber devices within 15 minutes. 0-2147483647, default:
0.
C
13
no dsl alarm-channel-profile
<
name
>
Removes the specified DSL alarm channel profile.
C
13
show dsl alarm-channel-profile
[
name
]
Displays the names of all the DSL alarm channel profiles if a name
is not specified or the contents of the specified DSL alarm channel
profile.
E
13
dsl alarm-channel-profile <
name
>
Enters the sub-command mode for configuring the specified DSL
alarm channel profile.
C
13
exit
Leaves the DSL alarm channel profile configuration sub-command
mode.
C
13
xtuc-15min-errcoding-
threshold <
threshold
>
Configures the number of Code Violations (incorrect cyclic
redundancy check) allowed on the system within 15 minutes. 0-
2147483647, default: 0.
C
13
xtuc-15min-corrected-
threshold <
threshold
>
Configures the number of corrected error blocks allowed on the
system within 15 minutes. 0- 2147483647, default: 0.
C
13
Table 116
VDSL Commands Summary (continued)
COMMAND
DESCRIPTION
M
P
Summary of Contents for IES4005M
Page 4: ...Contents Overview IES4005M User s Guide 4...
Page 13: ...13 PART I Introduction and Hardware Installation...
Page 14: ...14...
Page 20: ...Chapter 2 IES Chassis IES4005M User s Guide 20...
Page 38: ...Chapter 4 Line Cards IES4005M User s Guide 38...
Page 42: ...Chapter 5 Power Supply Unit IES4005M User s Guide 42...
Page 46: ...Chapter 6 Fan Module IES4005M User s Guide 46...
Page 58: ...Chapter 7 Cables IES4005M User s Guide 58...
Page 64: ...Chapter 8 Hardware Installation IES4005M User s Guide 64 Figure 36 Removing a Line Card 1 2 3...
Page 65: ...65 PART II Commands...
Page 66: ...66...
Page 78: ...Chapter 9 The CLI IES4005M User s Guide 78...
Page 124: ...Chapter 13 Switch Features IES4005M User s Guide 124...
Page 150: ...Chapter 20 MTU IES4005M User s Guide 150...
Page 164: ...Chapter 23 Static Route IES4005M User s Guide 164...
Page 192: ...Chapter 25 VLAN IES4005M User s Guide 192...
Page 204: ...Chapter 26 VoIP IES4005M User s Guide 204...
Page 210: ...Chapter 27 IEEE 802 1x Authentication IES4005M User s Guide 210...
Page 211: ...211 PART III Troubleshooting Specifications Appendices and Index...
Page 212: ...212...
Page 220: ...Chapter 28 Hardware Troubleshooting IES4005M User s Guide 220...