79 / 121
User Manual 3000SP
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
7.
Once the photovoltaic system has been activated, check that:
a.
The value of consumption shown on the screen remains constant as the photovoltaic
power increases.
b.
Depending on the photovoltaic production, the system will operate according to the
system's working mode.
c.
The value of PV production shown on the display is in line with the real photovoltaic
production visible on the photovoltaic inverter.
8.
If the above are not verified, check the CT positioning and direction by consulting the sections on
correct installation and initial start-up.
8.1.
Checking the settings
1.
Below is a summary of all the settings on the device, which you can find in the system info menu. In
particular, check that the parameters indicated are correct. To access this menu, from the main screen:
1.1.
Press the first key from the left;
1.2.
Press the third ↓ key twice;
1.3.
Enter the “System Info” menu by pressing the fourth key;
1.4.
To scroll through the images, press the third ↓ key.
RS485 Address
: check that it has a value of 01 so that you can monitor your systems via the app or website.
Country
: Check that the country code is correct for the regulation in force.