Battery (V)
Indicates the voltage of the battery pack expressed in Volts
Charge current
Indicates the current at which the battery pack is currently being charged
Discharge
current
Indicates the current at which the battery pack is currently being
discharged
Charge level
Indicates the charge percentage of the battery pack
Battery Cycles
Indicates the number of complete charging and discharging cycles
performed by the battery pack
Battery Temp.
Indicates the temperature measured on the cells of the battery pack
2)
Set %Charge Mode
Select “2. Set %Charge Mode” and press “OK” to enter the menu for setting this %Charge. In
this mode, the user can select one or more time intervals (both hourly and daily) during which
the battery will be forced to charge, also drawing power from the grid if the power supplied by
the photovoltaic system is not sufficient. The maximum charge level (SOC) and the power with
which the battery will be recharged can also be set.
Set %Charge Mode
Rules. 0: Enable
From To DOD Charge
21h00m - 06h00m 090% 1000W
Effective date
Dec. 22 - Mar. 21
Weekdays
Mon. Tue. Wed. Thu. Fri. Sat. Sun.
3)
Set Hourly Mode
Select “3. Set Hourly Mode”, then press “OK” to enter the interface of the set charge/discharge mode.
In this mode, it is possible to select a forced charging and discharging period for the battery, as well
as the power to be used for performing these operations.
Note: this mode is normally used to check that the 3000SP inverter is correctly charged and
discharged. Therefore, this mode is not recommended during normal operation of the system.
Below is an example of the screen.