48 / 121
User Manual 3000SP
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
9)
Minimum discharge voltage
Select “9. Min Discharge Voltage (V)” and press “OK” to enter the menu for setting the minimum
discharge voltage. Press the “Up” and “Down” keys to change the value of the minimum discharge
voltage. Press “OK” to move to the next digit and then confirm the setting; wait for “OK” to appear on
the display.
When setting this parameter for Pylontech batteries, refer to the table in section 6.2; for different
battery models, refer to the relative datasheet.
10)
End-of-discharge voltage (only for DEFAULT batteries)
Select “11. End-of-discharge V” and press “OK” to enter the menu for setting the end-of-discharge voltage.
Press the “Up” and “Down” keys to change the value. Press “OK” to move to the next digit and then
confirm the setting; wait for “OK” to appear on the display.
When setting this parameter, refer to the relative datasheet of the battery used.
Note: This setting is very important for lead-acid batteries, while it is not so important for lithium
batteries with BMS.
11)
End-of-charge Voltage (only for DEFAULT batteries)
Select “11. End-of-charge V” and press “OK” to enter the menu for setting the end-of-charge voltage. Press
the “Up” and “Down” keys to change the value. Press “OK” to move to the next digit and then confirm the
setting; wait for “OK” to appear on the display.
When setting this parameter, refer to the relative datasheet of the battery used.
Note: This setting is very important for lead-acid batteries, while it is not so important for lithium
batteries with BMS.
12)
Save
Select “Save” and press “OK” to save all the settings.
2.
Delete Energy Data
Select “2. Delete Energy Data” and press “OK.” The display will show “Enter PWD!” Press “OK” to enter the
password “0001” using the “Up” and “Down” keys to select the number and “OK” to move to the next digit.
If the display shows “Incorrect, try again!” press the “Menu/Back” key and enter the password again.
When the correct password is entered, the menu for resetting the statistics will open and the data relating
to the energy produced and consumed will be automatically deleted in the appropriate section of the
main menu.