21 / 121
User Manual 3000SP
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
The batteries can be recharged from the excess photovoltaic production or by using the forced charge mode
indicated in the “% charge mode” section of this manual.
4.2.
Connecting a Pylontech battery
4.2.1.
Connecting a single battery
This cable must be connected to the battery by inserting the RJ45 (8 pin) plug into the appropriate
connection:
1.
In the case of Pylontech batteries, insert the plug into the CAN port of the single battery.
Figure 11 - Pylontech communication cable to be inserted into the battery communication input
2.
Ensure that the order of the DIP switches remains at the factory settings (all down in the OFF position).
3.
Connect the ground cable to the battery through the threaded hole.
NOTE
: When connecting Pylontech batteries, use the communication cable contained in the inverter kit, as
shown in the figure.