ZXR10 8900 Series Hardware Installation Manual
Since fibers are slight and easy to be damaged in packing and
shipping, they should be cabled and bound on the office site. Each
optical interface should be connected with two fibers, one for data
sending and the other for data receiving. Be aware of the TX/RX
symbol on the panel and prevent them from being plugged incor-
rectly.
When the ZXR10 8900 is connected to other devices, the fiber
terminal forms are as shown in
Table 13
.
T
ABLE
13 F
IBER
T
ERMINAL
F
ORMS
S/N
Card type
Local-end fiber
terminal form
Remote-end fiber terminal
form
1
ST-XG-12GE-RJ454SFP
LC/PC-
2
ST-XG-24GE-RJ454SFP
LC/PC-
3
ST-12GE-SFP4RJ45
LC/PC-
4
ST-24GE-SFP4RJ45
LC/PC-
5
ST-XG-1XGE-XEN
SC/PC-
6
ST-XG-2XGE-XEN
SC/PC-
These products should be
purchased according to the
type of interface of the
customer’s interconnecting
device specified in the
contract. In addition, the
customer’s requirement of
optical connectors should also
be considered.
Note the following points when installing the fibers:
�
Fibers should be cabled in pair. Do not turn the fibers to 90
degrees while cabling. To bend the fiber, turn it into a round
or arc with a radius of no less than 40mm.
�
Fibers should be cabled smoothly instead of roughly, and bound
with a moderate strength.
�
Symbols at both ends of a fiber should be clear. The mean-
ings of the symbols should indicate the corresponding serial
numbers and the correspondence between racks and between
rows.
�
Prevent the fibers from being bent if possible. Do not bind the
fibers with cable clips roughly.
Label Types
Transverse
English Labels
Transverse English labels on panels and connectors are used on
connectors or panels where the paste areas are more than label
90
Confidential and Proprietary Information of ZTE CORPORATION