Start-up
|
-
"
__is
1:1
|
-
"
1:1
Suspension
Select parameter
"__is"
Enter the installation's type of suspension
Start-up
|
-
"
__i1
23.00
|
-
"
23.00
Gearbox i1:i2
Select parameter
"__i1"
Input of i1 of the gearbox ratio i1:i2
Possible only for asynchronous motors
Start-up
|
-
"
__i2
1
|
-
"
1
Gearbox i1:i2
Select parameter
"__i2"
Input of i2 of the gearbox ratio i1:i2
Possible only for asynchronous motors
Start-up
|
-
"
Q
600
kg
|
-
"
600
Nominal load
Select parameter
"Q"
Enter the elevator installation's rated load
Start-up
|
-
"
CONFIG
01: ZA_IO
|
-
"
01: ZA_IO
Con
fi
guration
Select parameter
"CONFIG"
Con
fi
guration of the digital inputs according to the used control system and type of
communication
Start-up
|
-
"
MO_DR
Left
|
-
"
Left
Motor rotation direc-
tion
Select parameter
"MO_DR"
Changing the rotating direction of the motor
It must be observed the with triggering the input RV1 the cabin drives upwards
Start-up
|
-
"
BR
Off
|
-
"
3*NO
Brake monitor
Select parameter
"BR"
De
fi
nition of the brake monitoring
Start-up
|
-
"
P1P2
Off
|
-
"
PTC
Motor temp. monitor
Select parameter
"P1P2"
Motor temperature monitoring
Start-up
|
-
"
K_START 1.0
|
-
"
1.0
Control vers. at start
Select parameter
"K_START"
Start gain
Multiplicative factor for the parameter "Controller/SPD_KP"
Increasing the PI controller during the start-up
Translation of the original operating instructions
ZETADYN 4C
Start-up
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
55/204
8