Error no.
Error text
Error cause
M S
830
CAN: Timeout Enab.-
Det.
Error:
Control system gives command "Enable Operation" not within T_CMD
Adjustment:
Increase time for T_CMD
831
CAN: Timeout Dis. Op.
Error:
Control system gives command "Disable Operation" not within T_CMD
Adjustment:
Increase time for T_CMD
832
CAN: Timeout Shut-
down
Error:
Control system gives command "Shutdown" not within T_CMD. Occurs by
closing the brakes.
Adjustment:
Increase time for T_CMD
833
CAN: Timeout Dis. Vol.
Error:
Control system gives command "Disable Voltage" not within T_CMD. Occurs at
end of travel.
Adjustment:
Increase time for T_CMD
840
CAN: ENC. Info missing
Error:
The object "Encoder Info" was not written to the frequency inverter by the
control
14.5.11
Error 9xx
•
Fatal errors which can only be acknowledged by switching off the ZETADYN 4
Error no.
Error text
Error cause
M S
905
MOP:HW-SW Error
Error:
Hardware or software error occurred after switch-on. After 60 s, the
frequency inverter switches to "Wait-Switch off"
Remedy:
Check the connectors between the Control Unit and Modul Print
check the fuse on the Switching Power Print
no Modul Print existing
check EEprom on the Modul Print
906
ZR_ERR by start
Error:
No signal at BC input during ZETADYN 4 start-up
Remedy:
Check wiring
Use the ZArec display to check for an error at the ZArec
908
PFU: No function
Error:
When switching on the frequency inverter, the monitor contact of the
power feedback unit is not closed
Remedy:
Check connection of the feedback unit function monitor,
Check feedback unit function monitor
●
910
BC: No function
Error:
When switching on the frequency inverter, the monitor contact for the
brake chopper or brake resistor is not closed
Remedy:
Check the temperature monitor for the Brake-Chopper or Brake
resistor,
check the temperature monitoring for the Brake-Chopper or Brake-Resistor,
911
BRxx: Overload
Error:
The continious braking power of the Brake resistor is exceeded by 150
% within 120 s
The frequency inverter switches off during travel
Remedy:
Check the con
fi
guration of the BR-type
Check the connected BR
●
912
BC: Fault
Error:
Monitor contact for brake chopper or brake resistor opens during fre-
quency inverter operation
Remedy:
Check the temperature monitor for the Brake-Chopper or Brake
resistor,
check the temperature monitoring for the Brake-Chopper or Brake-Resistor,
Translation of the original operating instructions
ZETADYN 4C
Error diagnosis
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
143/204
1
4
Error
diagnosis