14.2
LED
A LED is available to diagnose the ZETADYN 4. The LED lights in various colours.
1
1
LED position
Status of the ZETADYN 4 with standard activation
LED colour
LED status
Operation condition
green
fl
ashing once per sec-
ond
Standstill
green
fl
ashing twice per sec-
ond
Travel
Condition of the DCP connection
LED colour
LED status
Operation condition
red
fast
fl
ashing
With activated DCP function, the DCP connection is not present or is
defective
green
On
With activated DCP function, the DCP connection is
fl
awless
red / green
Slow alternat-
ing
fl
ashing
The DCP function is not activated in a trouble-free DCP connection
(only DCP3/DCP4)
Condition of the CAN connection
LED colour
LED status
Operation condition / error status
green
fl
ashing once
per second
Operation Mode "Stopped"
green
fast
fl
ashing
Operation Mode "Preoperational"
green
on
Operation Mode "Operational"
red
Off
no error, connection is in order
red
fl
ashing once
per second
CAN error counter has exeeded the warning limit of 96 errors
red
On
Bus off, reset of the controller is necessary
It is possible, that an operation condition and an error state occur at the same time and that they are
indicated by the LED at the same time.
Translation of the original operating instructions
ZETADYN 4C
Error diagnosis
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
129/204
1
4
Error
diagnosis