Calculating the available UPS power:
x
1 rating plate
- Control systempower consumption
- Electromechanical brakes power consumption
- Other consumers (car light,
…
) power consumption
=
Available UPS_power [W]
Information
Entering the UPS power determines the type of UPS evacuation.
Suf
fi
cient power:
An evacuation trip with the characteristics of an evacuation with optimum UPS
power is implemented.
Not enough power:
An evacuation trip with the characteristics of an evacuation with minimal UPS
power is implemented.
CAUTION!
Caution!
Setting the value for P_UPS too high can lead to an overloading or destruction of the UPS.
(7) Copying the parameters
In the menu
Parameter set 2/COPY
, select the function
PARA->2
. After copying, the parameter is
once again OFF.
Parameter set 2
|
-
"
COPY
Off
|
-
"
PARA1
R
2
Copy parameter
Information
The power failure detection and type of evacuation must be parameterised before copying the
parameters. Only a lower speed of the motor is possible because of the lower mains supply. The
maximum possible speeds for V_2 and V_3 are calculated during the copying process.