Dist. - - - - - - - - - - -
03
sa: 0.00 s21: 0.52m
sr:^0.00 s31: 1.45m
s1: 0.00 sd: 0.52m
Page 03: Dist
Line 2:
sa: current position of car in the shaft
s21: calculated deceleration path V_2
R
V_1
s20: calculated deceleration path V_2
R
Standstill (only in DCP02/DCP04)
Line 3:
sr: current direction of travel, current total route
s31: calculated deceleration path V_3
R
V_1
s30: calculated deceleration path V_3
R
Standstill (only in DCP02/DCP04)
Line 4:
s1: current travel path with positioning speed V_1 (not used in DCP02 / DCP04)
sd:real deceleration path V_3
R
V_1 or V_2
R
V_1
The display can be frozen by pressing the button.
Mot - - - - - - - - - - - -
04
zzz
_ _ _ _ _ _ _+0 %
real: 0rpm 0V
prog: 0rpm +0.0A
Page 04: Mot
Line 2:
Bar chart of motor speed
Slip in %
Load angle in
°
Line 3:
Actual motor speed
Motor voltage
Line 4:
Target motor speed
Motor current
If the motor has been correctly adjusted, the slip is nearly proportional to the motor
’
s rated
current (e.g. 50% motor current = 50% slip).
The display can be frozen by pressing the button.
MotDat - - - - - - - - - -
05
I: 11.0A n: 60rp
U: 360V f:10 Hz
p: 10
MotDat - - - - - - - - - -
05
I: 11.0A n: 1450rp
cos:0.88 f: 50.0Hz
I0: 3.8A TR: 316ms
Page 05: MotDat
Display of the motor data entered in the
“
Motor name plate
”
menu:
Line 2:
Rated current
Nominal speed
Line 3:
Nominal voltage
Rated frequency
Line 4:
Number of pole pairs
Line 2:
Rated current
Nominal speed
Line 3:
cos phi
Rated frequency
Line 4:
Magnetization current
Rotor time constant
Translation of the original operating instructions
ZETADYN 4C
Parameter list
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
96/204