Safety Brake
Press inspection!
[esc]
Start capture release by pressing the inspection run push-button
Function successful!
Function faile!
0.0s 4.0A
- - - - - - -> jerk1
Abort inspection run
in both cases.
Stop inspection
SB_INFO 1
[ESC]
Information
If required, the parameters impulse amplitude, impulse time, impulse pause and number of impulses
can be changed in the
Capture device
menu.
Possible errors during safety gear mode
Error no.
Error description
1
The travelling was interrupted too early by the user.
Travel command has to be longe existent.
2
No absolute encoder existent.
Check encoder connection.
3
Absolute value could not be read out from the absolute value encoder.
Check encoder cable.
10
Asymetric motor current. Difference over 12.5%.
Check motor phases / contactors.
30
The brake monitor indicates that the brakes are open, although the fre-
quency inverter has not yet opened them.
Check brake monitoring respectively the brakes.
40
Motor contactors do not switch.
50
Brake does not switch.
71
SIN / COS - Error
72
Missing SSI module
73
Missing SSI dialogue
74
EnDat Light Error
75
EnDat Amplitude Error
76
EnDat Position Error
77
EnDat Supply Error
Translation of the original operating instructions
ZETADYN 4C
Special functions
R-TBA12_01-GB 1415
Part.-No. 00163371-GB
162/204