![background image](http://html1.mh-extra.com/html/zetron/model-25/model-25_product-manual_3538775081.webp)
Programming - Front Panel
025-9567E
73
Table 23. Two-Tone 1000-Call Code Plans Supported by the Model 25
Plan #
Name
Plan #
Name
Plan #
Name
00 Motorola
B
10 Motorola M
20
Motorola Y
01 Motorola
C
11 Motorola N
21
Motorola MT
02 Motorola
D
12 Motorola
P
22 GE
X
03 Motorola
E
13 Motorola
Q
23 GE
Y
04 Motorola
F
14 Motorola
R
24 GE
Z
05 Motorola
G
15 Motorola S
25
Reach
06 Motorola
H
16 Motorola
T
26 Modified
General
07 Motorola
J
17 Motorola
U
27 General
Alternate
08 Motorola
K
18 Motorola
V
28 General
09 Motorola
L
19 Motorola
W 29 Special
Extended
Question 3 - Timing Assignment
Once you respond to “Question 2”, the unit will now display the prompt for “Question 3”:
The Two-Tone format requires that timing for the duration of the first tone, the gap, and the
second tone is provided. The expected entry for this question is a single digit. Table 24 lists
the timings supported by the Model 25. Please note that if you selected Reach as the paging
code plan, the alternate timings “6” and “7” are used.
Table 24. Two-Tone Page Tone Timings
Timing #
1
st
Tone
Gap
2
nd
Tone Group Call
Type
0 1.00 0.00 3.00 8.00
Mot/GE
1 0.40 0.00 0.80 8.00
Mot
2 1.00 0.00 3.00 6.00
NEC-B
3 1.00 0.25 3.00 6.00
NEC-A
4 1.00 0.00 1.00 4.00
NEC-C
5 0.40 0.00 0.80 4.00
NEC-M
6 0.50 0.00 0.50 3.00
NEC-L
7 0.40 0.00 0.40 3.00
NEC-D
Alternate REACH Timings 6 and 7
6 0.13 0.00 0.13 1.40
REACH
Fast
7 2.00 0.00 0.70 4.50
REACH
Slow
Note: All timings are in seconds