Upgrade the software of the ICX-500 to the latest version. Upgrade is done from the web
interface of the gateway. This will ensure that the system has the latest features, bug fixes
and security updates.
2.4. Status LEDs
The ICX-500 Gateway has a number of status LEDs. The same LEDs are located both in front
and at the rear side of the unit.
LED
Description
Power Steady green when power is applied to the ICX-500
Status Flashing green when the ICX is running
Fault
Steady amber when the system reports an error. The LED will be lit during
application or system reset, or if there is a temperature alarm.
Active
Steady blue when the ICX-500 is operational.
In a system with redundant servers, the Active LED will be lit on the operational
gateway, and not lit on the standby gateway
Link
Steady green when the ethernet link 0 or 1 is up. There is one LED for each
ethernet port
RX/TX Flashing when receiving or transmitting data on ethernet port 0 or 1.
2.5. Fault Relay
The fault relay will trigger when the system reports an error. In normal operation the relay is in
Normally Closed Position (NC), which means it will change position on power outage (Failsafe).
Fault is reported:
•
During Application or System reset
•
If there is a Temperature alarm (Thresholds are 75C on PCB, 95C on CPU)
•
If Power failure
2.6. User Configuration
AlphaPro is the Windows application used for configuration of the ICX-500 system. Configuration
of user data, such as Directory Numbers, Direct Access Keys, Group Calls etc. is done from
AlphaPro.