ICX 500 Gateway
Doc.no.A100K12202
Page 32
oldest log file will be deleted, until the remaining space is below 20MB. I.e., you will loose one day
of logging each time a log file is deleted.
Log Space in Local Filesystem
Clean up
will remove 10% of the oldest log content.
Delete
will delete the complete log file.
3.3.6. Licensing
License Installation
1. When Zenitel receives an order for ICX licenses, a
Product Key
will be sent by e-mail in
return
2.
Download a
Fingerprint File
of the ICX product on which licenses are to be installed. This
is done from the web interface:
System Configuration > Licensing.
3. Log on to the
IC Asset Management System
(AMS). This is a web page on internet.
4. In the AMS, under the
Product Key
section, identify the product key received from Zenitel,
and assign an "End Customer" from the dropdown list in the rightmost column.
5. If the end customer is not in the list, select
Add New End Customer
under the
End
Customers
section, then assign the End Customer to the product key.
6. Select an end customer from the list of End Customers and select
Create Site Node
. You
are now prompted to upload the Fingerprint File of the ICX product.
7. When the Site Node is created, click on this node. Select
Add Licenses
and enter the
quantity required from the licenses available, then
Add License
8. You can now download a
License File
or copy the license text.
9. In the Web interface of the ICX-500 or ICX-AlphaCom Core, go to System Configuration
> Licensing, and
Upload
the license file, or alternatively paste the license text.