SM-18001-rev.1
5-21
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
No.
Items
Optional Function
Individual
Setting
Setting
Condition
Contents
95
L3
Not Prepared
-
-
Not Used (Use as 00 conditions)
96
L4
Fan Speed during
Energy-Saving Forced
Thermo-OFF
Ducted
High
-
-
Not Used (Use as 00 conditions)
Ducted
Medium
Slim
○
00
01
Not Available
Available
97
L5
Not Prepared
-
-
Not Used (Use as 00 conditions)
98
L6
Not Prepared
-
-
Not Used (Use as 00 conditions)
99
L7
Not Prepared
-
-
Not Used (Use as 00 conditions)
100
L8
Not Prepared
-
-
Not Used (Use as 00 conditions)
101
L9
Auxiliary Heater OFF at Defrosting
Operation
○
00
01
Heater ON
Heater OFF
102
LA
Not Prepared
-
-
Not Used (Use as 00 conditions)
103
Lb
Not Prepared
-
-
Not Used (Use as 00 conditions)
104
P1
Setting Temperature
×
00
01
Every 1
o
F (0.5
o
C)
Every 2
o
F (1
o
C)
105
P2 Not Prepared
-
-
Not Used (Use as 00 conditions)
106
P3
Thermistor Selection
×
00
01
02
03
Inlet Air Thermistor
Outlet Air Thermistor
Thermistor of Wired Controller
Remote Sensor
107
P4
Display of Thermistor Temperature
×
00
01
Not Available
Available
108
P5
Setting Temperature Display during
Fan Operation
×
00
01
Dispalyed
Undispalyed
109
P6
ECO Button Operation
×
00
01
Available
Not Available
110
P7 Menu Button Operation
×
00
01
Not Available
Available
111
P8 Not Prepared
-
-
Not Used (Use as 00 conditions)
112
P9 Not Prepared
-
-
Not Used (Use as 00 conditions)
113
PA Not Prepared
-
-
Not Used (Use as 00 conditions)
114
Pb
Not Prepared
-
-
Not Used (Use as 00 conditions)
115
PC
Not Prepared
-
-
Not Used (Use as 00 conditions)
116
q1
Auxiliary Heater Setting
○
00
01
Not Available
Available
117
q2
Auxiliary Heater ON Compensation
(for Auxiliary Heater Setting)
○
00
01
02
03
04
05
06
07
08
09
-3
o
F (-1.5
o
C)
-3
o
F (-2
o
C)
-4
o
F (-2.5
o
C)
-5
o
F (-3
o
C)
-6
o
F (-3.5
o
C)
-7
o
F (-4
o
C)
-8
o
F (-4.5
o
C)
-9
o
F (-5
o
C)
-1
o
F (-0.5
o
C)
-2
o
F (-1
o
C)
118
q3
Auxiliary Heater OFF Compensation
(for Auxiliary Heater Setting)
○
00
01
0
o
F (0.0
o
C)
1
o
F (0.5
o
C)
Summary of Contents for CIDH018B21S
Page 2: ......
Page 10: ...viii SM 18001 rev 1...
Page 15: ...SM 18001 rev 1 1 1 INSTALLATION 1 Installation...
Page 19: ...SM 18001 rev 1 2 1 OPERATION 2 Operation...
Page 22: ......
Page 23: ...SM 18001 rev 1 3 1 TROUBLESHOOTING 3 Troubleshooting...
Page 75: ...MAINTENANCE SM 18001 rev 1 4 1 4 Maintenance...
Page 130: ......
Page 172: ......
Page 173: ...SM 18001 rev 1 6 1 FIELD WORK INSTRUCTIONS 6 Field Work Instructions...
Page 182: ...6 10 SM 18001 rev 1 FIELD WORK INSTRUCTIONS 6 8 Mollier Chart for R410A f t 3 l b...
Page 183: ...SERVICE PARTS LIST SM 18001 rev 1 7 1 7 Service Parts List...
Page 185: ......
Page 186: ...2018 Johnson Controls Inc SM 18001 rev 1 Code No LIT 12013047 Revised February 2019...