2-2
IM 253421-01E
2.2
Operation Keys and Function Display
TRIG
SETUP
Holds the displayed value. The HOLD
indicator lights. Pressing the key again turns
OFF the indicator and releases the hold.
SHIFT
LOCAL
INTERFACE
SHIFT
SETUP
OUTPUT
RESET
INTEG SET
RESET
STOP
START
ENTER
SHIFT
HOLD
SHIFT
HOLD
SHIFT
SHIFT HARMONICS
START
SHIFT
MEMORY
STOP
SHIFT
MODE
V RANGE
A RANGE
A RANGE
V RANGE
FUNCTION
Sets the filter, averaging, scaling, computation, external
sensor input, measurement synchronization source, MAX
hold, and the initialization of the set-up information (see
sections 4.2, 4.3, 4.5 to 4.11, and 12.2).
LOCAL
SHIFT
DC
SCALING
AVG
FILTER
STORE
RECALL
HARMONICS
M W
h
k
A
h
m V
Hz
M W
k
A
deg
var
TIME
FUNCTION
AUTO
MODE
TRIG
MAX HOLD
HOLD
CAL
INTEGRATOR
HARMONICS
INTERFACE
OUTPUT
SHIFT
REMOTE
MEMORY
INTEG SET
ENTER
A RANGE
V RANGE
START
LOCAL
SETUP
STOP
RESET
AUTO
FUNCTION
FUNCTION
m V
PF
M W
k
A
m V
VA
V MEAN
RMS
A OVER
V OVER
SAMPLE
A
B
C
MODE
Indicators for operation conditions
Shows sampling, voltage/current overrange and
measurement mode.
Shows the voltage range setting menu (section 4.4).
Shows the current range setting menu (section 4.4).
Switches between modes (section 4.1).
AUTO indicator
Lights up when range is AUTO.
Sets the displayed function
(chapter 5, sections 6.3 and 7.4).
Function/unit display
Shows the setting menu for harmonics ON/OFF, PLL
source, and element selection (sections 7.2 and 7.3).
Shows the setting menu for storing/recalling
measurement data and set-up information (chapter 8).
When the REMOTE indicator is lit, the remote
function will be canceled. When the REMOTE
indicator is not lit, the setting menu for
communication/printing will appear.
Shows the setting menu for communication/printing
(sections 9.9, 10.5, and 11.3).
Shows the setting menu for communication output items, D/A
output, plotter/printer output and comparator output (sections 9.3,
9.5 to 9.9, and 10.6).
Indicators for operating functions
When a function is set and in operation, this indicator will light up.
When in the HOLD condition this results in
updating the displayed value.
For decreasing the voltage/current range,
and for setting of functions/values.
For increasing the voltage/current range,
and for setting of functions/values.
For verifying the set range/function/value.
Moves the cursor of a value from left to right.
SHIFT
Moves the decimal point from left to right.
Starts integration (see section 6.3).
Stops integration (see section 6.3).
Sets the integration value and elapsed time of
integration to zero (0) (see section 6.3).
Shows the setting menu for integration
mode/type/time, and rated integration time
(see sections 6.2 and 9.3).
Turns ON/OFF the MAX hold function.
When turned ON, the MAX HOLD indicator lights.
This is the same as the MAX hold setting under
the SETUP key (section 4.8).
MAX HOLD
CAL
SHIFT
ENTER
Performs zero level compensation
(section 12.3).