Number of Displayed Digits (Display Resolution)
The number of displayed digits (display resolution) for voltage, current, active power, apparent power, reactive
power, and so on is as follows:
• If the value is less than or equal to 60000: Five digits.
• If the value is greater than 60000: Four digits.
For details, see appendix 4 in the getting started guide, IM WT1801-03EN. When the range rating (rated value
of the specified measurement range) is specified, the Σ functions of the voltage, current, active power, apparent
power, reactive power, and so on, are set to the decimal place and unit of the element with the lowest number of
displayed digits (display resolution) in the wiring unit. For details about the display resolution during integration,
see “Number of Displayed Digits (Display Resolution)” under “Integrated Power (Watt hours).”
Display Item (ITEM)
The display item options vary depending on the current display.
• Numeric data display format
•
4-, 8-, and 16-value displays (4 Items/8 Items/16Items)
•
•
•
Single Harmonics and Dual Harmonics Lists (Hrm List Single/Dual; option
•
•
•
•
•
•
High speed data capturing display items
For a list of the measurement functions and their descriptions, see “Items That This Instrument Can Measure.”
Example of How Measurement Functions Are Displayed in the Numeric Data Display
True rms voltage of element 1
Urms1
Element 1
True rms value
Voltage
Simple average of the currents of the elements in wiring unit ΣA
Idc
Σ
A
Σ function of wiring unit ΣA
Simple average
Current
Voltage of the 20
th
order of element 2
U2
(20)
Harmonic order 20
Element 2
Voltage
Simple average of the fundamental currents of the elements in wiring unit ΣB
I
Σ
B
(1)
Σ function of wiring unit ΣB
Order 1 (fundamental wave)
Current