3-14
<Toc>
<3. Programming>
IM 05E01B02-41E
1st Edition : May 31,2000-00
3.5
Program Parameter Map
Operating display
key
Segment 1
Program pattern 1
key
key
key
SET/ENT
key
Press this key for more than 3 seconds.
SET/ENT
Program Parameter Setting Display
LSP1
E28A
E28B
E27A
E27B
E26A
E26B
E25A
E25B
E24A
E24B
E23A
E23B
E22A
E22B
E21A
E21B
1.WZ1
1.WTM
2.WZ1
2.WTM
3.WZ1
3.WTM
4.WZ1
4.WTM
5.WZ1
5.WTM
RCY
RST
REN
Evn
ONn
OFFn
TYn
PEn
TSP1
TIME
TR.RT
PID
JC
Segment 2
Evn
ONn
OFFn
TYn
PEn
TSP1
TIME
TR.RT
PID
JC
PID
STC
SSP1
Press
the key
for more than
3 seconds to switch
to an operating
display.
SET/ENT
LOC
local mode set
sub menu
PROG
programming
main menu
PRG
A
programming
sub menu
MENU:PROG/PRG
#2
SEGno. input
SEG
=
0
MENU:PROG/PRG
#2
SEGno. input
SEG
=
1
MENU:PROG/PRG
#2
SEGno. input
SEG
=
2
MENU:PROG/PRG
#1
PTno. input
PTN
=
1
key
SET/ENT
key or
key
key or
key
1st group of
wait zones
1st group of
wait times
2nd group of
wait zones
2nd group of
wait times
3rd group of
wait zones
3rd group of
wait times
4th group of
wait zones
4th group of
wait times
5th group of
wait zones
5th group of
wait times
Number of
repetitions
Start-of-repetition
segment number
End-of-repetition
segment number
key
SET/ENT
Setpoint for
local-mode operation
Local event-28
type
Local event-28
setpoint
key
SET/ENT
key
SET/ENT
key
or
key
DISP
key
DISP
DISP
key
SET/ENT
Event number
On time of
time event
Off time of
time event
PV event type
PV event setpoint
Final target setpoint
Time-set
segment time
Ramp-set
segment time
PID group number
Junction code
key
SET/ENT
key
or
key
key
SET/ENT
key
SET/ENT
key
SET/ENT
Local event-27
type
Local event-27
setpoint
Local event-26
type
Local event-26
setpoint
Local event-25
type
Local event-25
setpoint
Local event-24
type
Local event-24
setpoint
Local event-23
type
Local event-23
setpoint
Local event-22
type
Local event-22
setpoint
Local event-21
type
Local event-21
setpoint
PID group number for
local-mode operation
STC= –1
STC
≠
–1
The parameter “PID” is shown for
segment PID parameters when the
setup parameter “ZON” is set to 0.
n = 1 to 8.
If EVn = 1 to 16, then this parameter
refers to time events 1 to 16.
If EVn = 21 to 28, then this parameter
refers to PV events 1 to 8.
“TIME” is shown when the Segment
Setting Method (SEG.T) parameter
is set using a time setpoint; “TM.RT”
is shown when the Segment Setting
Method (SEG.T) parameter is set
using a ramp grade setpoint.
The controller is factory-set to
show “TIME”.
The parameter “PID” is shown for segment
PID parameters when the setup parameter
“ZON” is set to 0.
key or
key
key or
key
key or
key
Starting target
setpoint
Start code
Event number
On time of
time event
Off time of
time event
PV event type
PV event setpoint
Final target setpoint
Time-set
segment time
Ramp-set
segment time
PID group number
Junction code
Parameters of program pattern 1