IM 1E10C1-E
11-11
11. PARAMETER LIST
Name
Data Range, Units
Default
Value
R/W
Description
Indicator
of SE
Pulse scale
0.0000 to 30000
0
W
Sets pulse rate.
F02
Pulse low cut
0 to 100%
3
W
Sets low cut width of pulse output.
F03
Pulse width
(00) 50% Duty
50% Duty
W
Selects pulse width.
F04
(01) 0.5 ms
(02) 1 ms
(03) 20 ms
(04) 33 ms
(05) 50 ms
(06) 100 ms
Disp select
(00) PV % rnge
PV% rnge
W
Selects display items on flowmeter indicator.
d01
(01) PV
(02) Totl
(03) Rev. totl
(04) Diff. totl
(05) PV %rnge/Totl
(06) PV/Totl
(07) PV %rnge/PV
(08) PV %rnge/Rev.totl
(09) PV/Rev.totl
(10) PV %rnge/Diff.totl
(11) PV/Diff.totl
Fl user sel
(00) Not provided
Not
W
Selects whether PV is displayed with user-defined unit.
d02
(01) Provided
provided
Fl user span
0 to 30000
100
W
Sets value dsiplayed in “PV” at 100% output when “Fl user sel”
d03
is provided.
Total/pulse
(00) No damp
Damp
W
Selects whether instantaneous flow rate values or damped ones
n01
(01) Damp
are used for totalization and pulse output.
Output mode
(00) On active
On active
W
Selects active level of status output set in “Output function”
n02
(01) Off active
(except “Alarm out”).
Empty pipe
(00) Alarm
No alarm
W
Selects alarm effectiveness when flow tube is not filled with
n07
(01) No alarm
fluid.
Manufacturer
Yokogawa
Yokogawa
R
Displays “Yokogawa’.
—
Dev id
—
Its own
R
Displays device ID.
—
ID No.
Write protect
Yes
No
R
Displays status of “Write Protect”.
—
No
Universal rev
—
—
R
Displays version of universal commands.
—
Fld dev rev
—
—
R
Displays version of communication commands for field device.
—
Software rev
—
—
R
Displays version of software for field device.
—
Enable wrt 10min
Enter characters
—
W
Release write protection when the password set in “New
—
Password” is entered.
New password
Enter characters
—
W
Sets new password up to 8 characters.
—
Software seal
(00) Keep
Keep
R
Displays software seal status.
—
(01) Break