11. PARAMETER LIST
Line size
0.01 to 300.0 mm/inch
100.0
W
Sets flow tube nominal size in selected unit.
b07
PV Damp
0.05 to 200.0 sec.
3.0
W
Sets damping time constant of output.
b02
Tag
Enter characters
—
W
Sets tag no. up to 8 characters.
—
Descriptor
Enter characters
—
W
Sets user-defined characters up to 16.
—
Message
Enter characters
—
W
Sets user-defined characters up to 32.
—
Date
01/01/00 to 12/31/99
0
W
Sets month/day/year.
—
Base bol unit
(00) k Cum
m
W
Selects volume unit of flow span.
b04
(01) Cum
(02) L
(03) Cucm
(04) M gal
(05) k gal
(06) gal
(07) m gal
(08) k bbl
(09) bbl
(10) m bbl
(11) u bbl
(12) m
(13) ft
Base time unit
(00) d
s
W
Selects time unit of flow span.
b05
(01) h
(02) min
(03) s
Velocity check
0 to 32.767 m/s
R
Displays span in m/s.
b13
Size unit
(00) mm
mm
W
Selects flow tube nominal size unit.
b06
(01) in
MF
0.2500 to 3.0000
1.0000
W
Sets meter factor.
b08
(Actual flow test data has been entered.)
Flow dir
(00) Forward
Forward
W
Selects flow direction.
b14
(01) Reverse
PV % rnge
–110.0 to 110.0%
R
Displays instantaneous flow rate in %.
A10
Rate limit
0 to 10%
5
W
Sets the level to reduce output fluctuation.
n03
Dead time
0 to 15 sec
0
W
Sets the dead time to reduce output fluctuation. When “0” is set,
n04
“Rate limit” is not available.
Power synch
(00) Yes
Yes
W
Selects synchronization between excitation frequency and
n05
(01) No
power frequency.
Power freq
47.00 to 63.00 Hz
50.00
W
Sets AC power frequency for DC power supply.
b12
Total unit
(00) n UNIT/P
PULSE/s
W
Selects totalization rate unit.
E01
(01) u UNIT/P
(“UNIT” in the selection on the left represents the “Base vol
(02) m UNIT/P
unit” selected.)
(03) UNIT/P
(04) k UNIT/P
(05) M UNIT/P
(06) PULSE/s
Total scale
0.0000 to 30000
0
W
Sets totalization rate.
E02
Total low cut
0 to 100%
3
W
Sets low cut width of totalization.
E03
Name
Data Range, Units
Default
Value
R/W
Description
Indicator
of SE