10.5 Motion Parameter Details
10.5.3 Monitor Parameter List
10-54
IW
12
Output Current
Reports the output current from the Inverter.
Unit: Inverter rated current/8,192.
You can check the current unit setting in the Unit
monitor parameter (IW
06).
IW
13
Motor Speed (Option)
Reports the motor speed during operation.
Unit: According to the O1-03 Inverter parameter.
You can check the current unit setting in the Unit
monitor parameter (IW
06).
IW
14
Torque Reference (Option)
Reports the torque reference.
Unit: 0.1%
You can check the current unit setting in the Unit
monitor parameter (IW
06).
IW
15
Encoder Count PG1
Reports the counter value.
IW
16
Frequency Reference (Option)
Reports the frequency reference from the
Inverter.
Unit: According to the O1-03 Inverter parameter.
You can check the current unit setting in the Unit
monitor parameter (IW
06).
IW
17
Analog Input A2
Unit: 0.1%
IW
18
Main Bus Voltage (Option)
Unit: 1 VDC
IW
19
Alarm Code
Reports the Inverter alarm code.
IW
1A
Warning Code
Reports the Inverter warning code.
IW
1B
Multi-Function
Output Terminal
Bit 0: Terminal 1 Status
0: OFF, 1: ON
Bit 1: Terminal 2 Status
0: OFF, 1: ON
Bit 2: Terminal 3 Status
0: OFF, 1: ON
Bit 3: Terminal 4 Status
0: OFF, 1: ON
Bit 4: Terminal 5 Status
0: OFF, 1: ON
Bit 5: Terminal 6 Status
0: OFF, 1: ON
Bit 6: Terminal 7 Status
0: OFF, 1: ON
Bit 7: Terminal 8 Status
0: OFF, 1: ON
Bit 8: Terminal 9 Status
0: OFF, 1: ON
Bit 9: Terminal 10 Status
0: OFF, 1: ON
Bit A: Terminal 11 Status
0: OFF, 1: ON
Bit B: Terminal 12 Status
0: OFF, 1: ON
Bits C to F
Reserved
IW
1C
Analog Input A3
Unit: 0.1%
IW
1D
Multi-Function
Input Terminal
Bit 0: Terminal 1 Status
0: OFF, 1: ON
Bit 1: Terminal 2 Status
0: OFF, 1: ON
Bit 2: Terminal 3 Status
0: OFF, 1: ON
Bit 3: Terminal 4 Status
0: OFF, 1: ON
Bit 4: Terminal 5 Status
0: OFF, 1: ON
Bit 5: Terminal 6 Status
0: OFF, 1: ON
Bit 6: Terminal 7 Status
0: OFF, 1: ON
Bit 7: Terminal 8 Status
0: OFF, 1: ON
Bits 8 to F
Reserved
IW
1E
Analog Input A1
Unit: 0.1%
IW
1F
Encoder Count PG2
Reports the count value.
IW
20
Monitor data set in F6-23
Reports the result of the monitor set in the F6-23
Inverter parameter.
IW
21
Monitor data set in F6-24
Reports the result of the monitor set in the F6-24
Inverter parameter.
Continued on next page.
Continued from previous page.
Register
No.
Name
Description
Summary of Contents for SVC
Page 34: ...2 6 4 Reference Output Timing 2 20 2 6 5 Precautions When Combining with Other Modules 2 21...
Page 383: ...5 2 Absolute Encoders 5 2 6 Position Management Method for Each Machine Operation Type 5 42...
Page 387: ...5 2 Absolute Encoders 5 2 6 Position Management Method for Each Machine Operation Type 5 46...