9 Input Assemblies (Drive Produces)
YASKAWA ELECTRIC
SIEP C730600 92A YASKAWA AC Drive Option SI-EN3 Technical Manual
45
166
Parameter F7-39
Default: NetRef and NetCtrl (Low Byte)
–
–
–
–
–
–
NetCtrl
NetRef
Parameter F7-39
Default: NetRef and NetCtrl
Parameter F7-40
Default: Drive Software Version (Low Byte)
Parameter F7-40
Default: Drive Software Version (High Byte)
Parameter F7-41
Default: Not Used
Parameter F7-33
Default: Not Used
Parameter F7-33
Default: Not Used
Parameter F7-42
Default: Not Used
20
40
–
–
–
–
–
–
Assy. 116
F7-32 Error
Assy. 116
F7-31 Error
41
Assy. 116
F7-30 Error
Assy. 116
F7-29 Error
Assy. 116
F7-28 Error
Assy. 116
F7-27 Error
Assy. 116
F7-26 Error
Assy. 116
F7-25 Error
Assy. 116
F7-24 Error
Assy. 116
F7-23 Error
21
42
–
–
–
–
–
–
Assy. 166
F7-42 Error
Assy. 166
F7-41 Error
43
Assy. 166
F7-40 Error
Assy. 166
F7-39 Error
Assy. 166
F7-38 Error
Assy. 166
F7-37 Error
Assy. 166
F7-36 Error
Assy. 166
F7-35 Error
Assy. 166
F7-34 Error
Assy. 166
F7-33 Error
<1> Selectable with F7-33 to F7-42.
Parameter
Data
Running
Running
0: Stop
1: Forward or Reverse Running
Zero Speed
Zero Speed
0: Running
1: Stop or DC Injection Braking
REV Running
Reverse Running
0: Not Reverse Running
1: Reverse Running
Fault Reset
Fault Reset command from Network
0: Fault Reset command is not from network
1: Fault Reset command is from network
Speed Agree
Speed Agree
0: No Speed Agree
1: Speed actual at speed reference
Ready
Drive Ready
0: Not Ready
1: Ready
Alarm
Drive Alarm
0: No Drive Alarm
1: Alarm
Faulted
Drive Fault
0: No Drive Fault
1: Fault
OPE
OPE Fault
0: No oPE
fault
1: oPE
Uv
Under Voltage
0: No Under Voltage
1: Under Voltage
Input
Instance
Word Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
EtherNet_conditional_E.book 45 ページ 2016年6月28日 火曜日 午後11時30分