5 Installation Procedure
YASKAWA ELECTRIC
SIEP C730600 92A YASKAWA AC Drive Option SI-EN3 Technical Manual
19
Installing the Option on a GA700 Drive
Prepare the Drive for the Option
Before beginning the installation procedure:
1. Wire the drive and make the proper connections to drive terminals according to the manual packaged with the drive.
2. Verify that the drive functions normally.
for an exploded view of the drive with the option and related components for reference in the
installation procedure.
Figure 16
Figure 16 Drive Components with Option
Install the Option
Remove the front cover of the drive before installing the option. Refer to the drive instruction manual for directions on
removing the front cover. Cover removal varies depending on drive size. This option can be inserted only into the
CN5-A
connector located on the drive control board.
DANGER!
Electrical Shock Hazard. Do not inspect, connect, or disconnect any wiring while the drive is energized. Failure to comply
will cause death or serious injury. Before servicing, disconnect all power to the equipment and wait for at least the time specified on the
warning label. The internal capacitor remains charged even after the drive is de-energized. The charge indicator LED will extinguish
when the DC bus voltage is below 50 Vdc. When all indicators are OFF, measure for unsafe voltages to confirm the drive is safe.
1.
Affix the LED label (E) in the appropriate position on the drive front cover (D).
Figure 17
Figure 17 Affix the LED Label
A – Insertion point for CN5 connector
I – Connector CN5-A
B – SI-EN3 option
J – Connector CN5-B
(Not available for communication
option installation.)
C – Included screws
D – Drive front cover
E – LED label
K – Connector CN5-C
(Not available for communication
option installation.)
F – Keypad
G – Option modular connector CN1
H – LED Status Ring board
H
C
K
G
J
I
B
A
D
E
F
A1000
D
E
A1000
EtherNet_conditional_E.book 19 ページ 2016年6月28日 火曜日 午後11時30分