6 Related Drive Parameters
24
YASKAWA ELECTRIC
SIEP C730600 92A YASKAWA AC Drive Option SI-EN3 Technical Manual
F7-03
(3E7)
IP Address 3
Sets the static/fixed IP address.
Parameter F7-03 sets the third most significant octet.
Default: 1
Min: 0
Max: 255
F7-04
(3E8)
IP Address 4
Sets the static/fixed IP address.
Parameter F7-04 sets the fourth most significant octet.
Default: 20
Min: 0
Max: 255
F7-05
(3E9)
Subnet Mask 1
Sets the static/fixed Subnet Mask.
Parameter F7-05 sets the most significant octet.
Default: 255
Min: 0
Max: 255
F7-06
(3EA)
Subnet Mask 2
Sets the static/fixed Subnet Mask.
Parameter F7-06 sets the second most significant octet.
Default: 255
Min: 0
Max: 255
F7-07
(3EB)
Subnet Mask 3
Sets the static/fixed Subnet Mask.
Parameter F7-07 sets the third most significant octet.
Default: 255
Min: 0
Max: 255
F7-08
(3EC)
Subnet Mask 4
Sets the static/fixed Subnet Mask.
Parameter F7-08 sets the fourth most significant octet.
Default: 0
Min: 0
Max: 255
F7-09
(3ED)
Gateway Address 1
Sets the static/fixed Gateway address.
Parameter F7-09 sets the most significant octet.
Default: 192
Min: 0
Max: 255
F7-10
(3EE)
Gateway Address 2
Sets the static/fixed Gateway address.
Parameter F7-10 sets the second most significant octet.
Default: 168
Min: 0
Max: 255
F7-11
(3EF)
Gateway Address 3
Sets the static/fixed Gateway address.
Parameter F7-11 sets the third most significant octet.
Default: 1
Min: 0
Max: 255
F7-12
(3F0)
Gateway Address 4
Sets the static/fixed Gateway address.
Parameter F7-12 sets the fourth most significant octet.
Default: 1
Min: 0
Max: 255
F7-13
(3F1)
Address Mode at Startup
Selects how the option address is set.
0: Static
1: BOOTP
2: DHCP
Default: 2
Range: 0 to 2
F7-14
(3F2)
Duplex Mode Selection
Selects duplex mode setting.
0: Auto/Auto
1: Half/Half
2: Full/Full
3: Half/Auto
4: Half/Full
5: Auto/Half
6: Auto/Full
7: Full/Half
8: Full/Auto
Default: 1
Range: 0 to 8
F7-15
(3F3)
Communication Speed Selection
Sets the communication speed
10: 10 Mbps
100: 100 Mbps
101: 10/10 Mbps
102: 100/100 Mbps
Default: 10
Range: 10 to 102
F7-17
(3F5)
EtherNet/IP Speed Scaling Factor
Sets the scaling factor for the speed monitor in EtherNet/IP Class ID 2AH
Object.
Default: 0
Min.: -15
Max.: 15
F7-18
(3F6)
EtherNet/IP Current Scaling Factor
Sets the scaling factor for the output current monitor in EtherNet/IP Class
ID 2AH Object.
Default: 0
Min.: -15
Max.: 15
F7-19
(3F7)
EtherNet/IP Torque Scaling Factor
Sets the scaling factor for the torque monitor in EtherNet/IP Class ID 2AH
Object.
Default: 0
Min.: -15
Max.: 15
No.
(Addr.
Hex)
Name
Description
Values
EtherNet_conditional_E.book 24 ページ 2016年6月28日 火曜日 午後11時30分