9 Input Assemblies (Drive Produces)
42
YASKAWA ELECTRIC
SIEP C730600 92A YASKAWA AC Drive Option SI-EN3 Technical Manual
Parameter
Data
Running
Running
0: Stop
1: Forward or Reverse Running
Zero Speed
Zero Speed
0: Running
1: Stop or DC Injection Braking
REV Running
Reverse Running
0: Not Reverse Running
1: Reverse Running
Fault Reset
Fault Reset command from Network
0: Fault Reset command is not from network
1: Fault Reset command is from network
Speed Agree
Speed Agree
0: No Speed Agree
1: Speed actual at speed reference
Ready
Drive Ready
0: Not Ready
1: Ready
Alarm
Drive Alarm
0: No Drive Alarm
1: Alarm
Faulted
Drive Fault
0: No Drive Fault
1: Fault
OPE
OPE Fault
0: No oPE
fault
1: oPE
Uv
Under Voltage
0: No Under Voltage
1: Under Voltage
Local/Remote
Status of Run command from Network
0: Run command is not from Network
1: Run Command is from Network
Multi-Function Digital Output
Terminal M1/M2
0: Terminal M1/M2 OFF
1: Terminal M1/M2 ON
Multi-Function Photo Coupler 1
Terminal P1
0: Terminal P1 OFF
1: Terminal P1 ON
Multi-Function Photo Coupler 2
Terminal P2
0: Terminal P2 OFF
1: Terminal P2 ON
ZSV
Zero Servo Completed
0: –
1: Completed
Motor Speed
Monitor parameter U1-05
Torque Actual
Output Torque
Shows the Torque Reference.
Value displays in 0.1% units.
PG Count Value
PG Pulse Count
Frequency Command
Monitor parameter U1-01
Output Frequency
Actual Drive Speed
Monitors drive output frequency.
Unit depends on o1-03.
Unit is not affected by Speed Scale SS.
Output Current
Actual Output Current
Monitors drive output current.
Unit is 0.01 A
Unit is not affected by Current Scale CS.
EtherNet_conditional_E.book 42 ページ 2016年6月28日 火曜日 午後11時30分