Using the Digital Operator
7.2.6 Checking the Motor Model
7 -34
5.
Press the DSPL/SET Key to display the encoder type and resolution code.
Encoder Type
Encoder Resolution
Encoder Type
Encoder Resolution
Code
Type
Code
Resolution
00
Incremental encoder
13
13 bits
01
Absolute encoder
16
16 bits
17
17 bits
20
Reserved
6.
PresstheDSPL/SETKeytodisplaytheServopack’sspecialspecificationcode(Y-specifica-
tion code).
This example shows specification code “Y10”
(Indicated in decimal).
7.
Press the DATA/ENTER Key to return to the auxiliary function mode display. Pressing the
DATA/ENTER Key after the above display 3. to 5. will also return to the auxiliary function
mode display.
This ends checking motor type procedure.
Using the Panel Operator
1.
Press the MODE/SET Key to select the auxiliary function mode.
2.
Press the Up or Down Cursor Key to select the user constant Fn011.
7
SGDH
-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA