![YASKAWA E-II SGM H Series User Manual Download Page 182](http://html1.mh-extra.com/html/yaskawa/e-ii-sgm-h-series/e-ii-sgm-h-series_user-manual_3266058182.webp)
User Constant Settings and Functions
5.7.2 Selecting an Absolute Encoder
5 -94
5.7.2 Selecting an Absolute Encoder
Select the absolute encoder usage with the following user constant.
Pn002.2
Absolute Encoder Usage
Factory
Setting:
0
Speed, Torque
Control,
Position Control
“0” in the following table must be set to enable the absolute encoder.
Pn002.2 Setting
Contents
0
Use the absolute encoder as an absolute encoder.
1
Use the absolute encoder as an incremental encoder.
Note
This user definition goes into effect when the power is turned OFF after the
change has been made.
5.7.3 Handling Batteries
In order for the absolute encoder to retain position data when the power is turned OFF, the data
must be backed up by a battery.
J
J
Installing the Battery at the Host Device
Lithium battery, by Toshiba: ER6VC3, 3.6 V, 2000 mAh
J
J
Battery Provided for Servopack
Lithium battery: JZSP-BA01 (includes battery and connector)
Battery: Toshiba, ER3 V, 3.6 V, 1000 mAh
Battery carrying space
Batter connector (CN8)
Figure 5.2
Servopacks with Capacities of 30 W to 5.0 kW
5