![YASKAWA E-II SGM H Series User Manual Download Page 249](http://html1.mh-extra.com/html/yaskawa/e-ii-sgm-h-series/e-ii-sgm-h-series_user-manual_3266058249.webp)
7.1 Basic Operation
7 -9
Using the Panel Operator
1.
Press the MODE/SET Key to select the user constant setting mode.
2.
Press the Up or Down Cursor Key to select the user constant number to set. (Pn507 is se-
lected in this example.)
3.
Press the DATA/SHIFT Key for a minimum of one second to display the current data for the
user constant selected in step 2.
4.
Press the Up or Down Cursor Key to change to the desired value of “00085”.
As you keep pressing the Up or Down Cursor Key, and the display changes faster.
5.
Press the DATA/SHIFT Key for a minimum of one second to save the data. The display will
flash.
6.
Press the DATA/SHIFT Key once more for a minimum of one second to display the user
constant number again.
This has changed the setting of the user constant Pn507 from 100 to 85.
Repeat steps 2. to 6. as often as required.
Press the DATA/SHIFT Key for a maximum of one second to shift to a higher (left) digit.
User constant numbers that are not defined are skipped during Operator operations.
7
SGDH
-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
IMPORTANT
INFO
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]