![YASKAWA E-II SGM H Series User Manual Download Page 266](http://html1.mh-extra.com/html/yaskawa/e-ii-sgm-h-series/e-ii-sgm-h-series_user-manual_3266058266.webp)
Using the Digital Operator
7.2.3 Automatic Adjustment of the Speed and Torque Reference Offset
7 -26
Using the Panel Operator
1.
Input the (intended) 0V reference voltage from the host controller or external circuit.
Servomotor
Slow Rotation
(Servo ON)
Servopack
Servo OFF
Host
Controller
0V Speed
or Torque
Reference
2.
Press the MODE/SET Key to select the auxiliary function mode.
3.
Press the Up or Down Cursor Key to select the user constant Fn009.
4.
Press the DATA/SHIFT Key for a minimum of one second, and the display will be as shown
below.
5.
Press the MODE/SET Key, and the following display will flash for one second. The refer-
ence offset will be automatically adjusted.
Flashing for
one second
6.
Press the DATA/SHIFT Key for a minimum of one second to return to the auxiliary function
mode display.
This completes the speed/torque reference offset automatic adjustment.
7
SGDH
-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]