Holding Brake Setting
Set the following user constants to adjust brake ON timing so the holding brake is applied when
the Servomotor stops.
Pn507
Brake Reference
Output Speed Level
Unit:
r/min
Setting
Range:
0 to 10000
Factory
Setting:
100
Speed/Torque
Control,
Position Control
Pn508
Timing for Brake
Reference Output
during Motor Operation
Unit:
10ms
Setting
Range:
10 to 100
Factory
Setting:
50
Speed/Torque
Control,
Position Control
Set the brake timing used when the servo isturned OFFby input signal /S-ON(CN1-40) or when
an alarm occurs during Servomotor with brake operation.
/S-ON input
Power OFF by /
S-ON (CN1-40) in-
put or alarm oc-
currence
Motor speed
(r/min)
Pn-507
/BK output
Stop by dynamic brake
or coast to a stop.
(Pn001.0)
Pn508
Release
brake
Servo ON
Hold with brake
Servo OFF
Brake ON timing when the Servomotor stops must be adjusted properly because Servomotor
brakes are designed as holding brakes. Adjust the user constant settings while observing equip-
ment operation.
/BK Signal Output Conditions During Servomotor Operation
The circuit is open under either of the following conditions:
1
Motor speed drops below the setting at Pn507 after servo OFF.
2
The time set at Pn508 has elapsed since servo OFF.
The actual setting will be the maximum speed even if Pn507 is set higher than the maximum
speed.