5.3 Setting Up the Servopack
5 -59
Contact Input Speed Control Selection (Contact Reference)
«
Speed Control (Analog Reference)
This mode controls speed by switching between contact reference and analog voltage reference
speed control. Analogvoltage referencespeed controlisenabledwhen both/P-CL (/SPD-A)and
/N-CL (/SPD-B) input signals are OFF (high level). See
5.2.6 Contact Input Speed Control.
Contact Input Speed Control Selection (Contact Reference)
«
Position Control (Pulse Train Reference)
This mode switches between contact reference speed control and pulse train reference position
control. Pulse train reference position control is enabled when both /P-CL (/SPD-A) and /N-CL
(/SPD-B) input signals are OFF (high level). See
5.2.6 Contact Input Speed Control.
Contact Input Speed Control Selection (Contact Reference)
«
Torque Control (Analog Reference)
Thismodeswitchesbetweencontactreferencespeedcontrolandanalogvoltagereferencetorque
control. Torque control using an analog voltage reference isenabled when both /P-CL (/SPD-A)
and /N-CL (/SPD-B) input signals are OFF (high level). See
5.2.6 Contact Input Speed Control.
Position Control (Pulse Train Reference)
«
Speed Control
(Analog Reference)
This mode switches between position and speed control through the /P-CON (/C-SEL) signal.
Position Control (Pulse Train Reference)
«
Torque Control
(Analog Reference)
This mode switches between position and torque control through the /P-CON (/C-SEL) signal.
Torque Control (Analog Reference)
«
Speed Control (Analog
Reference)
Thismode switchesbetween torque and speed control through the /P-CON(/C-SEL) signal. See
5.2.7 Using Torque Control.
Speed Control (Analog Reference)
«
Zero Clamp
This speed control mode is used to set the zero clamp function when the Servopack is stopped.
Zero clamp operates when the /P-CON (/ZCLAMP) signal is ON (low level). See
5.4.3 Using
the Zero Clamp Function.
Position Control (Pulse Train Reference)
«
Position Control
(Inhibit)
This mode controls positioning by inhibiting reference pulse input through the /P-CON (/IN-
HIBIT) signal. See
5.2.12 Using Reference Pulse Inhibit Function (INHIBIT)