Display
Refer to the Electronic Control System
Manual for 6LY3, available as a separate
volume, for details.
Display Function
Runtime Engine Data Tri-Screen
(Figure 5)
0
1
2
3
4
WTR TEMP
X1000
RPM
PSi
8 4
2615
0
100
100
250
1 1 4
Fa h
SINGLE
OIL PRES
0002023
Figure 5
This screen displays real time engine data
and alarm indications.
Alarm Indicators (Figure 6)
Alarm window appears with an audible
alarm when abnormal engine activity
occurs.
Note: When starting the engine, make it a
rule to check for any highlighted alarms. If
the system does not function normally,
contact your authorized Yanmar Marine
dealer and ask for diagnostics.
DUAL PORT
Alarms
HOT ENGINE
OVER REV
OIL PRESSURE
TURBO BOOST
GEAR OIL
ENG COM ERROR
MAINTENANCE
NETWORK
CHECK ENGINE
EMERGENCY
LOW VOLTAGE
ALTERNATOR
SEA WATER FLOW
LOW COOLANT
WATER IN FUEL
THROTTLE PROBLEM
0002024
Figure 6
Alarm Log Screen (Figure 7)
Alarm Log
061803
CONTACT YANMAR DISTRIBUTOR
17:04 - COM ERROR Y 025
P0120/FEB0 THROTTLE SENSOR
VALUE OUT OF RANGE.
CLR
Port Eng Alarms
EXIT
0002025
Figure 7
PRODUCT OVERVIEW
16
6LY3 LDC Operation Manual
© 2008 Yanmar Marine International