TROUBLESHOOTING
Troubleshooting by DTC Fault Codes
12/05
6LY3 Service Manual
13-47
© 2007 Yanmar Marine International
P0198/0 (Oil Temperature Too High)
DTC Fault Code
Fault
Diagnosis Procedure
1. Check the seawater pump impeller.
2. Check the seacock.
3. Check the seawater system.
4. Check the oil cooler.
5. Check the oil level.
6. Check the oil temperature sensor.
DTC
P0198/0
Temperature Too High
DTC / FMI
1. Condition, 2. Fault, 3. Time to Detect, 4. Display
Check Point
P0198/0
1. Key switch ON
2. Oil temperature is above 120°C (248°F)
3. 0.5 seconds
4. CHECK ENGINE on the TELEFLEX display
Oil system
Cooling seawater system
sensor
Fail Mode
Limited Operation
No limited operation
Fail Release
Yes
When the oil temperature goes below 115°C (239°F) for 0.5 seconds
Remarks
Normal oil temperature at rated speed is about 90°C (194°F).
DTC / FMI
Probable Cause
P0198/0
1. Seawater pump impeller
2. Seacock
3. Seawater system
4. Oil cooler
5. Oil volume
6. Oil temperature sensor