TURBOCHARGER
Turbocharger Periodic Inspections
9-10
6LY3 Service Manual
© 2007 Yanmar Marine International
Checking the Rotor Axial Play
1. Remove the turbocharger from the engine.
2. Cover all inlet openings to prevent any ingestion
of debris.
3. Install a magnetic dial indicator as shown in
Figure 9-4
.
4. Move the turbine / impeller back and forth in an
axial direction
(Figure 9-4, (6))
and measure
travel on the dial indicator.
5. Compare readings with the maintenance
standard limits that follow:
Figure 9-4
Figure 9-4
1 – Turbine Housing
2 – Oil Outlet
3 – Magnetic Base
4 – Dial Indicator
5 – Oil Inlet
6 – Move the turbine rotor shaft in an axial
direction.
Rotor Axial Play
0.06-0.09 mm (0.002-0.003 in.)
Limit: 0.11 mm (0.004 in.)
(6)
(5)
(2)
(1)
(
3
)
(4)
0005
8
97