TROUBLESHOOTING
Troubleshooting by Symptom
13-6
6LY3 Service Manual
© 2007 Yanmar Marine International
An engine data screen will not
display.
The battery voltage is low
(Discharging battery).
Check the electrolyte level and
the specific gravity of battery.
See Checking the Electrolyte
Level on page 12-4
.
Charge the battery or replace.
See Charging the Battery on
page 12-5
.
Check for a short.
See Alternator Wiring Diagram
on page 11-8
.
Battery will not charge.
Check the wires between the
alternator and the battery.
See Alternator Wiring Diagram
on page 11-8
.
Check the tension of the V-belt.
See Check the V-Belt Tension
on page 4-25
.
Check the alternator.
See Alternator on page 11-1
.
Wiring of the control system is
disconnected.
Connect the control system
wires.
See Alternator Wiring Diagram
on page 11-8
.
Connectors are not closed.
Close the connector according
to the manual.
See Remote Control Electronic
Control System (ECS) on
page 12-20
.
Contact failure of each
connector pin.
Check each connector terminal
and confirm continuity.
See Remote Control Electronic
Control System (ECS) on
page 12-20
.
Fuse burned out.
(IGN. PANEL: 10A)
Replace the fuse.
See Troubleshooting Fuses,
Relays and Harnesses on
page 13-21
.
Fuse burned out.
(ECU: 20A)
Replace the fuse.
See Troubleshooting Fuses,
Relays and Harnesses on
page 13-21
.
Fuse burned out.
(IGN. SIG: 10A)
Replace the fuse.
See Troubleshooting Fuses,
Relays and Harnesses on
page 13-21
.
Fuse burned out.
(IGN. 1st Station: 5A)
Replace the fuse.
See Troubleshooting Fuses,
Relays and Harnesses on
page 13-21
.
Fuse burned out.
(IGN. 2nd Station: 5A)
Replace the fuse.
See Troubleshooting Fuses,
Relays and Harnesses on
page 13-21
.
Detecting error.
(U0146 / 12)
➝
DTC:
See Troubleshooting by
DTC Fault Codes on
page 13-28
.
Trouble Symptom
Causes
Corrective Action
Remarks