TROUBLESHOOTING
Troubleshooting by DTC Fault Codes
12/05
6LY3 Service Manual
13-29
© 2007 Yanmar Marine International
TFX Diagnostic Screen Display Procedure 1
Figure 13-6
Figure 13-6
TFX Diagnostic Screen Display Procedure 2
Figure 13-7
Figure 13-7
When powered-up, the i5601E Digital Displays will initially display an introductory screen showing the software
revision level. They will then display one of the following four screens:
These screens show all of the key engine data and can be accessed by pushing a single button. The right-most
button allows the contrast and brightness to be set.
In the unlikely event that an engine fault occurs, a warning box appears in the
display showing the cause of the fault, and the action to take. “Press Any Key
To Continue.”
Pressing any key acknowledges the alarm and immediately switches the display to the Alarms screen. The
i5601E continues to beep until all alarm conditions (engine faults) have cleared. Unacknowledged alarms are
shown as flashing boxes. Press any key to acknowledge alarm boxes that may still be flashing, and they will then
change to a stready highlighted state.
Alarm blocks remain highlighted as long as the alarm condition (engine fault) remains and will automatically
reset to an un-highlighted state after the alarm condition has passed.
Engine Diagnostic Code Summary Screen
Note: The i5601E is an extremely versitle display. The four-left keys can be reconfigured to allow the user to
display whatever screens he or she desires. For additional operational details, refer to Appenbdix A and the
technical manual.
0006
3
20
BACK
EXIT
MORE
ON
OFF
BACK
i5601E Digital Display Setup
The i5601E was set up at the factory with the keys assigned and locked as shown on page 6 of this manual. This
mode is the default mode and allows start up and operation of the engine. It serves many applications quite well.
The i5601E Digital Display unit has many additional features and capabilities. This section of the book shows
the use of some of these features.
Changing the basic set up is typically accomplished in one of two ways.
1. Go to the systems menu and alter basic selections.
2. Enable the right arrow key on the basic screens to allow changing of the data shown in the default
displays.
To move around the menus use the softkeys at the bottom of the screen.
The function of a particular softkey changes from screen to screen to
whatever is most appropriate for the given screen.
To enter the Main Menu press and hold key 5 until the menu appears.
NOTE : Any changes to the setup menus may require reconfiguring the i5601E HOT KEY SETUP.
Keys
1
2
3
4
5
i5601E Menu Navigation
Performs the function indicated by a pop-up menu,
if present.
With no pop-up menu showing, briefly press to
display the Lighting & Contrast menu.
With no pop-up menu showing, press and HOLD
to display the MAIN MENU.
Buttons
“Down” Arrow moves menu selection down
“Up” Arrow moves menu selection up
“Right” Arrow acts on current menu item
“Back” Moves back to previous menu
Returns you to the previous menu or screen.
Decreases the setting of a selected menu item.
Moves the cursor arrow down to select the
next menu item in a list.
Exits the current menu and returns you to the
prior screen.
Increases the setting of a selected menu item.
Reveals additional keys and swaps them with
those currently shown.
Toggles the operational status of a currently
selected menu item.
Moves the cursor arrow up to select the
previous menu item in a list.
MAIN MENU
ALARMs / DIAGs
MONITOR SETTINGS
CALIBRATION
FACTORY SETTINGS
Password Protected
ALARMs / DIAGs
Diag Codes
Alarms
Network Status
Network Modes
MONITOR SETTINGS
HOT KEYS LOCK
Default Monitor
Beeper ON
About
Depth Offset
SPEED
Tach Range 0-3000
Language Menu
Units Menu
USER SETTINGS
Reset Main1 Time
Prog Shift Delay 0.0
Station Protect N
Split Range
Rev Throt Curv 1
Fwd Throt Curv 1
Docking Mode
TROLLING
Troll Mode SPLIT
Valve CAL
Max Throttle 50%
Lever 40%
SETUP TROLL VALVE
Trans Type ZF
RPM ENGAGE 450
FACTORY SETTINGS
Eng Display: PORT
Setup TROLL Valve
Fixed Shift Dry 0.0
SYSTEM SELECT
T Engage Dry 0.0
Lead Eng Port
Sync: Pwr Train
Set idle rpm
CALIBRATION
USER SETTINGS
TROLLING
0006
3
16